• AWWA ACE54317
Provide PDF Format

Learn More

AWWA ACE54317

  • Evaluation of UV Disinfection Systems for the Inactivation of Cryptosporidium
  • Conference Proceeding by American Water Works Association, 06/01/2001
  • Publisher: AWWA

$12.00$24.00


The LT2ESWTR, expected in 2002, will require public water utilities to achieve varying degrees of Cryptosporidium removal and inactivation depending on their source water quality and their water treatment process train. Ultraviolet (UV) disinfection is very effective against Cryptosporidium, produces negligible disinfection byproducts, and is the lowest cost technology available for achieving Cryptosporidium credits. In this study, the long-term performance of four UV disinfection systems treating finished water was evaluated at three surface water treatment plants over a one-year period. Two of the systems used low-pressure, high-output mercury arc lamps, one used conventional low-pressure lamps, and the last used medium-pressure lamps. All systems were designed to deliver a UV dose of 40 mJ/cm 2 . Water quality evaluations demonstrated that UV transmittance and factors deemed to influence fouling depend on the water source and water treatment used. Dose delivery was assessed using MS2 bioassay. Neither lamp fouling nor seasonal changes in water temperature had a notable impact on dose delivery by the UV reactors. The dependence of UV dose on UV transmittance was dependent on the reactor design. While lamp aging was observed, three of the reactors were able to maintain doses above 40 mJ/cm 2 and one was able to maintain a dose above 30 mJ/cm 2 for several thousands of hours. UV dose, however, did not correlate to UV intensity measured using on-line sensors. Overall, UV sensor readings were difficult to interpret. Unexplainable trending of UV sensor readings were observed indicative of either sensor degradation or sensor window fouling. The study indicates that with an appropriate lamp replacement period, UV systems may be sized to reliably meet a dose target over time. Further, the study indicates a need for improved UV intensity sensor performance and provides evidence supporting the need to use reference sensors to regularly check measurements made by on-line sensors. Includes 10 references, tables, figures.

Related Products

AWWA WQTC60611

AWWA WQTC60611

Comparison of an Anionic Polymer to No Polymer Addition for Treating Filter Backwash Water..

$12.00 $24.00

AWWA MTC64524

AWWA MTC64524

Integrated Approach to Construction and Startup of the 96 mgd Lakeview WTP for the Region of Peel..

$12.00 $24.00

AWWA INF52174

AWWA INF52174

Field Performance Monitoring of a Sliplined Watermain..

$12.00 $24.00

AWWA ACE59836

AWWA ACE59836

Water Conservation in Georgia Bringing Efficiency into Mainstream Thinking..

$12.00 $24.00