• AWWA ACE54379
Provide PDF Format

Learn More

AWWA ACE54379

  • The Use of Microfiltration and Reverse Osmosis to Treat Secondary Wastewater Treatment Plant Effluent and Provide High Quality Reclaimed Water
  • Conference Proceeding by American Water Works Association, 06/01/2001
  • Publisher: AWWA

$12.00$24.00


Imported water is a major resource for industry in California, but its ever-increasing costs are leading to alternative methods for meeting water supply needs. This paper discusses how the use of membrane technology for the treatment of wastewater effluent is helping one Southern California agency relieve its dependency on expensive imported water. It describes the treatment process and the performance of a facility that converts the wastewater effluent to high quality water suitable for industrial use. The West Basin Municipal Water District's Phase III Expansion project at their water recycling plant in El Segundo, California treats secondary effluent received from the City of Los Angeles' Hyperion Treatment Plant to provide water to the Chevron refinery. The purpose of the expansion is to provide high quality water suitable for use as boiler feed water in the Chevron refinery. Chevron requires two grades of water. The less stringent grade requires water quality of 0-mg/l calcium, 0-mg/l magnesium, 1.5-mg/l silica, 0.3 mg/l as CaCO3 total hardness, and 60 mg/l total dissolved solids. The higher quality grade provides water with 0-mg/l calcium, 0-mg/l magnesium, 0.1-mg/l silica, 0.03 mg/l as CaCO3 total hardness, and less than 5 mg/l total dissolved solids. To meet these requirements, the project provides microfiltration and reverse osmosis treatment of secondary effluent wastewater received from Hyperion. This paper will provide an overview of the project goals, the processes and the equipment necessary to achieve the goals, as well as the method of delivery of the construction project. Includes 6 references, tables, figures.

Related Products

AWWA ACE56251

AWWA ACE56251

City of Cocoa, Florida, Trenchless Technology Approach Using Horizontal Directional Drilling for Reh..

$12.00 $24.00

AWWA WQTC69488

AWWA WQTC69488

Short-Term Variations in DBP Concentrations at the Point of Entry to the Distribution System..

$12.00 $24.00

AWWA ACE58340

AWWA ACE58340

A Tool Kit for Water Efficiency Practitioners: Calculation Shortcuts and Rules of Thumb for Commerci..

$12.00 $24.00

AWWA IMTECH57854

AWWA IMTECH57854

Innovative Applications Using a CMMS for the Boston Water and Sewer Commission..

$12.00 $24.00