• AWWA MTC61080
Provide PDF Format

Learn More

AWWA MTC61080

  • A Two-fiber, Bench-scale Test of Ultrafiltration (UF) for Investigation of Fouling Rate
  • Conference Proceeding by American Water Works Association, 03/01/2005
  • Publisher: AWWA

$12.00$24.00


Experimental results are presented for a two-fiber, bench-scale test that wasdesigned to evaluate the effect of setpoint flux, backwash frequency and backwash time onlong-term fouling rate of low-pressure membrane systems. In this study, an ultrafiltration(UF) membrane was used to treat granular-media filtered, secondary wastewater effluent.The fouling rate as measured by the decline in specific flux over many backwash cycleswas disproportionately lower for a lower setpoint flux (50 vs. 65 L/m<sup>2</sup>/h) and higherbackwashing frequency (10 vs. 15 min). The increase in backwash time (1 min vs. 30 s)did not influence the removal of membrane pore blockage but reduced the rate of cake layerformation significantly on membrane surface. However, this effect was larger at the lowersetpoint flux. The comparison of bench-scale and pilot-scale test also shows that the two-fiber,bench-scale test is a very useful, first-cut approach for acquiring process designinformation for pilot- and full-scale operation. Includes 10 references, figures.

Related Products

AWWA JAW23801

AWWA JAW23801

Journal AWWA - Controlling Swampy Odors in Drinking Water ..

$15.00 $30.00

AWWA DSS60350

AWWA DSS60350

Design, Construction and Operation of Denver's New Recycled Water System..

$12.00 $24.00

AWWA JAW64847

AWWA JAW64847

Journal AWWA - Process-Train Profiles of NOM through a Drinking Water Treatment Plant..

$15.00 $30.00

AWWA JAW59515

AWWA JAW59515

Journal AWWA - Expanded Summary: Protecting Watersheds from Cryptosporidium in Manure: A Literature ..

$15.00 $30.00