• AWWA MTC64631
Provide PDF Format

Learn More

AWWA MTC64631

  • Effect of Aluminum and Ferric Coagulant Residuals Present after MF on NF Membrane Fouling
  • Conference Proceeding by American Water Works Association, 03/01/2007
  • Publisher: AWWA

$12.00$24.00


The effects of coagulant residuals on nanofiltration (NF) fouling wereinvestigated. Experiments were carried out with a pilot microfiltration(MF)-NFplant and a laboratory-scale MF-NF setup. The pilot influent was drawn from asedimentation basin after poly-aluminum chloride (PACl) coagulation. In the pilot,MF (PVDF membrane nominal pore size, 0.1 µm) permeates were transferred tothe NF modules (nominal NaCl rejection 55%; polyamide), which was operatedwith constant flux (0.6 m/day) and water recovery (95%) by adjusting the feedpressure. In the laboratory-scale experiment, groundwater was pretreated withPACl, alum, or ferric chloride in-line coagulation and MF; then the MF permeatewas pumped to an NF cross-flow cell with 0.6-m/d flux and 10% raw waterrecovery.The trans-membrane pressure of the NF in the pilot doubled in the 6 months ofoperation, although the mean silt density index of the NF feed water was 2.25,suggesting an absence of severe fouling by particulate matter. The aluminumconcentration in the NF influent was not high (average 30 µg/L), but analysis ofmembrane foulants revealed excessive accumulation of aluminum (46 mg/m<sup>2</sup>)as well as silicate (30 mg/m<sup>2</sup>), suggesting that aluminum residuals probablycaused the membrane fouling by forming alumino-silicates or aluminumhydroxide. In the laboratory-scale experiments, the permeability of NF declinedwhen the feed water contained residual aluminum at 18 µg/L or more, but notwhen the aluminum concentration was lower than about 9 µg/L. Thermodynamiccalculations and elemental analyses of the foulants recovered from themembranes indicated that the majority of inorganic foulants were compoundscomposed of aluminum, silicate, and possibly potassium. Includes 4 references, tables, figures.

Related Products

AWWA WQTC71421

AWWA WQTC71421

Shifting the Paradigm: The Concept of Sustainable Membrane Operation..

$12.00 $24.00

AWWA CSC94001

AWWA CSC94001

Feed Forward Chlorine Dose Control to Counteract Sudden Ammonia Increase in Water Purification Plan..

$12.00 $24.00

AWWA DSS60340

AWWA DSS60340

Practical Steps for Reducing Apparent Water Losses..

$12.00 $24.00

AWWA WQTC65770

AWWA WQTC65770

Removal of an Antimicrobial Compound by Sequential Photochemical and Biological Oxidation Processes..

$12.00 $24.00