• AWWA WQTC57037
Provide PDF Format

Learn More

AWWA WQTC57037

  • Test Pool Monitoring for the Howard Hanson Dam Additional Water Storage Project
  • Conference Proceeding by American Water Works Association, 11/01/2002
  • Publisher: AWWA

$12.00$24.00


This paper provides background information on Tacoma Water's water supply system, and summarizes Tacoma's involvement to date at monitoring the impacts on water quality resulting from a test of using the Corps of Engineers' Howard Hanson Reservoir for municipal water storage. During the spring and summer of 2002, the Corps and Tacoma conducted a test of the Additional Water Storage Project by storing and holding 20,000 acre feet of water behind Howard Hanson Dam (HHD) above the normal high pool of 1147 ft., taking the high pool elevation to 1167 ft. In addition to monitoring the structural integrity of the dam during the test pool, the Corps and Tacoma cooperated in monitoring the quality of the water stored to the new elevation. Seven monitoring stations were established within the reservoir. An eighth station was located at Tacoma's Headworks located about 3-1/2 miles downstream of HHD. Water quality parameters measured at these locations included turbidity, flavor profile analysis/flavor rating analysis, total coliform/fecal coliform, giardia and cryptosporidium, temperature, dissolved oxygen, conductivity and pH, total organic carbon, color, UV 254, ozone kinetics, total trihalomethane/haloacetic acid, algae, geosmin and MIB. All parameters were measured just below the water surface, and several were also taken at 10 ft, 20 ft, and 25 ft depths. Samples were analyzed either by Tacoma Water staff, or taken to private laboratories, or to the Seattle Water Department laboratory for analysis. In addition to monitoring water quality parameters, the twenty-foot elevation of newly-inundated reservoir shoreline was monitored for evidence of sloughing, a potential source of turbidity, during reservoir drawdown. Sampling began on April 15, 2002, when the pool was at elevation 1157 ft., ten feet above normal high pool. The reservoir reached its target high pool elevation of 1167 ft. on June 3, and remained at approximately this level through July 1,2002. Samples were taken in the reservoir from a boat every other week from April through November 2002. Samples obtained at the Tacoma Headworks were taken in front of the intake.

Related Products

AWWA ACE70630

AWWA ACE70630

Permitting of a Large California Membrane Filtration Installation..

$12.00 $24.00

AWWA ACE92201

AWWA ACE92201

Boston's Meter Downsizing Project: A One-Year Report..

$12.00 $24.00

AWWA ACE70553

AWWA ACE70553

Pilot Results of Three Systems for Nitrate Pretreatment at the city of Thornton, Colorado (Project #..

$12.00 $24.00

AWWA ACE60027

AWWA ACE60027

Advanced Pre-Treatment with Ion Exchange Technology for Organic Carbon Removal: CALFED Bay-Delta Pro..

$12.00 $24.00