• AWWA WQTC57056
Provide PDF Format

Learn More

AWWA WQTC57056

  • Development of Stringent Verification Procedures for Molecular Detection of Enteric Viruses in Water
  • Conference Proceeding by American Water Works Association, 11/01/2002
  • Publisher: AWWA

$12.00$24.00


Combining the use of conventional cell culture techniques with molecular methods for the detection of human enteric viruses in surface and groundwater allows detection of infectious enteroviruses producing cytopathic effects (CPE), as well infectious non-CPE enteroviruses. The objective of this study was to assay surface and groundwater samples for the presence of enteroviruses by combining cell culture and molecular techniques. Critical to the success of this study was the implementation and evaluation of a Quality Assurance/Quality Control (QA/QC) plan and determining if additional steps were necessary to increase the rigorousness of the plan and to ensure the validity of the results. Over 240 surface and groundwater samples were collected and processed using a modification of the Information Collection Rule for virus analysis. Samples assayed using Buffalo green monkey kidney (BGMK) and human colonic carcinoma (CACO-2) cell lines were observed for CPE over a period of 10 to 14 days. Positive CPE sample flasks were confirmed by secondary cell culture passage prior to molecular analysis, while negative CPE flasks were assayed by molecular techniques. Following total RNA extraction, RT-PCR was carried out using primers targeting the human enteroviruses. Confirmation of PCR results was accomplished by Southern blotting, hybridization of an internal digoxigenin-labeled probe, and chemi-luminescent detection. Controls incorporated during analyses included blind coding of samples, periodic positive and negative spike controls, cell culture positive and negative controls, PCR positive and negative controls, and incorporation of dUTP and UDG to prevent carry-over contamination during PCR. Includes 14 references, table, figures.

Related Products

AWWA ACE70630

AWWA ACE70630

Permitting of a Large California Membrane Filtration Installation..

$12.00 $24.00

AWWA ACE92201

AWWA ACE92201

Boston's Meter Downsizing Project: A One-Year Report..

$12.00 $24.00

AWWA ACE70553

AWWA ACE70553

Pilot Results of Three Systems for Nitrate Pretreatment at the city of Thornton, Colorado (Project #..

$12.00 $24.00

AWWA ACE60027

AWWA ACE60027

Advanced Pre-Treatment with Ion Exchange Technology for Organic Carbon Removal: CALFED Bay-Delta Pro..

$12.00 $24.00