• AWWA WQTC62377
Provide PDF Format

Learn More

AWWA WQTC62377

  • Development, Validation and Implementation of a Multiphase CFD Model for Optimization of Full-Scale Ozone Disinfection Processes
  • Conference Proceeding by American Water Works Association, 11/01/2005
  • Publisher: AWWA

$12.00$24.00


Drinking water ozonation is continually facing new challenges because of more and morestringent regulations on disinfection and disinfection byproducts. The commonly used CTapproach often underestimates disinfection efficiency, therefore it is not suitable to be used foroptimization of system design and operation. In this study, a two phase CFD model has beendeveloped to address all the major components of ozonation processes: contactor hydraulics,ozone mass transfer, ozone decay, microbial inactivation, and disinfection byproduct formationkinetics. The CFD model was applied to simulate ozone contactor performance at the MannheimWater Treatment Plant in Ontario, Canada. The results show that the CFD method predictssignificantly higher CT values than the traditional CT<sub>10</sub> method (up to 250%) using ozoneresiduals at 6 monitoring points within the contactor. The 13 year old Mannheim ozone systemhas recently been modified to include new liquid oxygen-fed ozone generators in order toenhance operational flexibility and remove some diffusers from the system. The modellingresults suggest that these changes have led to an increase in effective residence time. The CFDmodel was also applied to optimize ozone contactor performance at the DesBaillets WaterTreatment Plant in Montreal, Canada. Numerical results are in good agreement with full-scaletracer experimental data. The CFD predicted flow fields show that recirculation zones and shortcircuiting exist in the DesBaillets contactors. The current simulation results suggest that theinstallation of additional, appropriately located, baffles would increase the residence time andimprove disinfection efficiency. It is anticipated that the work will demonstrate that the CFDapproach is an efficient tool for improving the ozone disinfection performance of existing watertreatment plants and designing new ozonation systems. Includes 15 references, figures.

Related Products

AWWA WQTC71558

AWWA WQTC71558

Removal of Typical Perfluorinated Surfactants from Water Using Some Conventional Adsorbents..

$12.00 $24.00

AWWA DSS90031

AWWA DSS90031

Safe and Sanitary Procedures for Underwater Inspection of Your Reservoirs..

$12.00 $24.00

AWWA ACE70487

AWWA ACE70487

New Tools for Sustainable Energy Management Decisions..

$12.00 $24.00

AWWA ACE54315

AWWA ACE54315

Modeling Tools to Predict National Compliance Forecasts and DBP Exposure..

$12.00 $24.00