• AWWA WQTC65844
Provide PDF Format

Learn More

AWWA WQTC65844

  • Ozone Contactor Flow Visualization and Characterization Using 3-Dimensional Laser Induced Fluorescence
  • Conference Proceeding by American Water Works Association, 11/01/2007
  • Publisher: AWWA

$12.00$24.00


The number of water treatment facilities using ozone as a primary disinfectant isgrowing in places where surface waters are used as a source. Ozone disinfection in drinkingwater treatment facilities is often carried out in an ozone contactor that consists of multiplevertical or horizontal chambers to which ozone is fed by fine bubble diffusers (FBD). Thehydrodynamics of an ozone contactor strongly affect the overall conversion of all the chemicaland biological reactions (Roustan, et al, 1993; Henry & Freeman, 1995; Do-Quang, et al, 2000).Its effect is more pronounced for reactions with a relatively higher conversion (e.g., inactivationof C. parvum oocysts up to 99 to 99.9 percent) compared to reactions with a lower conversion(e.g., bromate formation from bromide is typically below 30 percent). Consequently, thereactor hydrodynamics could be optimized to minimize bromate formation while achievingtarget inactivation efficiency for C. parvum oocysts (Tang, et al, 2005; Kim, et al, 2006; Kim, etal, 2007).The impact of hydrodynamic conditions determined by such design variables oninactivation efficiency, which is a primary concern in ozone contactor design, was investigated.In particular, a three-dimensional laser-induced fluorescence (3D-LIF) was developed in thisstudy to visualize the mixing condition inside the ozone contactor by quantifying the entireinstantaneous tracer concentration field at very high resolution in three-dimensional space (Tian& Roberts, 2003) without disturbing the flow conditions (i.e. due to sampling). Varioushydrodynamic conditions within an ozone contactor including the non-ideal flow pattern, theeffects of flow rate, and the baffle opening size, were examined. Includes 9 references, figures.

Related Products

AWWA WQTC60611

AWWA WQTC60611

Comparison of an Anionic Polymer to No Polymer Addition for Treating Filter Backwash Water..

$12.00 $24.00

AWWA MTC64524

AWWA MTC64524

Integrated Approach to Construction and Startup of the 96 mgd Lakeview WTP for the Region of Peel..

$12.00 $24.00

AWWA INF52174

AWWA INF52174

Field Performance Monitoring of a Sliplined Watermain..

$12.00 $24.00

AWWA ACE59836

AWWA ACE59836

Water Conservation in Georgia Bringing Efficiency into Mainstream Thinking..

$12.00 $24.00