• AWWA WQTC69407
Provide PDF Format

Learn More

AWWA WQTC69407

  • Integrated Water Quality Modeling of a Wastewater Repurification Process
  • Conference Proceeding by American Water Works Association, 11/01/2008
  • Publisher: AWWA

$12.00$24.00


Water quality modeling was performed for the 13.2 million gallon per day (MGD) Gibson IslandAdvanced Water Treatment Plant (AWTP) in Brisbane, Australia. The AWTP includes high-rateclarification, microfiltration, reverse osmosis and advanced oxidation. The model incorporated differinginfluent water quality, multiple chemical injection points and multiple unit processes. The mainobjectives were to:understand how alkalinity and phosphorus levels would affect treated water stabilization;document the chemical system calculations;incorporate the addition of constituents into the water stream because of chemical injection;document the assumed operational control philosophy; and,optimize chemical costs, process performance and residual production.The AWTP Process included the following unit processes:chloramination and pH adjustment (sulfuric acid or caustic soda);coagulation with ferric chloride and polymer and high-rate clarification;microfiltration;pH adjustment;two-pass reverse-osmosis treatment;hydrogen peroxide/advanced oxidation ultraviolet light reactors; and,chemical conditioning with lime and carbon dioxide prior to storage or discharge.The AWTP processes were split into incremental systems, and each chemical injection point andtreatment process was treated individually. A combination of project-specific spreadsheet models and acommercially-available, spreadsheet-based water quality model was used. Models were runsequentially, so one system's effluent water quality became the next system's influent water quality. For each treatment strategy, multiple influent water quality scenarios were modeled to determine thechemical dosing requirements and resulting treated water quality. Includes tables, figures.

Related Products

AWWA WQTC71644

AWWA WQTC71644

Permeate Quality Comparison of MBR and Tertiary Membrane Filtration..

$12.00 $24.00

AWWA C209-06

AWWA C209-06

Cold-Applied Tape Coatings for the Exterior of Special Sections, Connections, and Fittings for Steel..

$37.00 $74.00

AWWA REUSE52091

AWWA REUSE52091

San Antonio Water System's Recycled Water Program: Edwards Aquifer Recharge Zone Irrigation Pilot St..

$12.00 $24.00

AWWA ACE99420

AWWA ACE99420

Evaluating Performance of Backwash Water Treatment Processes Using Indigenous Aerobic Bacterial Spor..

$12.00 $24.00